Use an ALARM to be notified when a sensor reading hits a specific value – frost for example. The system can notify you and/or anyone you program by phone or Email up to 9 repetitions

Step 1

TrainingGuideChapter5-a
Open the ALARM page

Click “ADD STATION” to select a station

Select a SENSOR to monitor

Click “MANUALLY ADD ALARM”


Step 2
TrainingGuideChapter5-b
The COLOR KEY indicates the ALARM STATUS.

Click the EDIT button to edit or setup an alarm

Step 3 - ALARM PROPERTIES (when)
TrainingGuideChapter5-c 
*** Select LESS THAN <=
or MORE THAN >=  
never select EQUAL=

Set TEMP and AVG.TIME

Optionally:
set BLACKOUT (no alarm) CHECKBOX and TIMES 

Step 4 – ALARM PROPERTIES (who)
TrainingGuideChapter5-d Set the TRIGGER (repeat calls)

Enter a “PHONE NUMBER” and click “ADD” (repeat for all phones to be called)

Optionally:
Set OUT of RANGE CHECKBOX and TIMEOUT


Step 5
TrainingGuideChapter5-e
Arm the ALARM by clicking the ALARM BUTTON

The alarm bar COLOR changes to green

Step 6
TrainingGuideChapter5-f
Disarm the ALARM by clicking the DISARM BUTTON (again)

The alarm bar COLOR changes back to orange

Step 7
TrainingGuideChapter5-g 
Once the system has sent out an alarm (alarm bar is red) it must be reset before it can alarm again.

Click on the RESET button
 

DOWNLOAD the Training Guide
Learn about ADVANCED METHODS
Return to the TABLE of CONTENTS
Sponsored by:

 Visit our web site to learn more...

Copyright 2009 - Wy'East RC&D
Login Register Privacy Statement Terms Of Use
Intelligent Netware :: 2-time SBA Champion-of-the-Year award winner for digital media, SEO marketing and web design for micro-enterprises